N-Terminal amino acid side-chain cleavage of chemically modified peptides in the gas phase: A mass spectrometry technique for N-terminus identification
peer-reviewed · Bioorganic & Medicinal Chemistry · 2006
| Date | 2006-09-01 |
| Type | peer-reviewed |
| Venue | Bioorganic & Medicinal Chemistry |
| Publisher | Elsevier BV |
| Contribution | adjacent |
| DOI | 10.1016/j.bmc.2006.05.060 |
| Citations (OpenAlex) | 28 |
Abstract
Although genome databases have become the key for proteomic analyses, de novo sequencing remains essential for the study of organisms whose genomes have not been completed. In addition, post-translational modifications present a challenge in database searching. Recognition of the b or y-ion series in a peptide MS/MS spectrum as well as identification of the b1 - and yn-1 -ions can facilitate de novo analyses. Therefore, it is valuable to identify either amino-acid terminus. In previous work, we have demonstrated that peptides modified at the epsilon-amino group of lysine as a t-butyl peroxycarbamate derivative undergo free radical promoted peptide backbone fragmentation under low-energy collision-induced dissociation (CID) conditions. Here we explore the chemistry of the N-terminal amino group modified as a t-butyl peroxycarbamate. The conversion of N-terminal amines to peroxycarbamates of simple amino acids and peptides was studied with aryl t-butyl peroxycarbonates. ESI-MS/MS analysis of the peroxycarbamate adducts gave evidence of a product ion corresponding to the neutral loss of the N-terminal side chain (R), thus identifying this residue. Further fragmentation (MS3) of product ions formed by N-terminal residue side-chain loss (-R) exhibited an m/z shift of the b-ions equal to the neutral loss of R, therefore labeling the b-ion series. The study was extended to the analysis of a protein tryptic digest where the SALSA algorithm was used to identify spectra containing these neutral losses. The method for N-terminus identification presented here has the potential for improvement of de novo analyses as well as in constraining peptide mass mapping database searches.
Methods and tools
- Peroxycarbamate N-terminal labelling: N-terminal t-butyl peroxycarbamate derivatives lose the N-terminal side chain in CID, identifying that residue and labelling the b-ion series to aid de novo sequencing.
Cites (8)
- PepNovo: de novo peptide sequencing via probabilistic network modeling (2005) crossref
- PEAKS: powerful software for peptide de novo sequencing by tandem mass spectrometry (2003) crossref
- Improved peptide sequencing using isotope information inherent in tandem mass spectra (2003) crossref
- Differential stable isotope labeling of peptides for quantitation and de novo sequence derivation (2001) crossref
- Implementation and Uses of Automated de Novo Peptide Sequencing by Tandem Mass Spectrometry (2001) crossref
- Quantitation and Facilitated de Novo Sequencing of Proteins by Isotopic N-Terminal Labeling of Peptides with a Fragmentation-Directing Moiety (2000) crossref
- A method for high-sensitivity peptide sequencing using postsource decay matrix-assisted laser desorption ionization mass spectrometry (1999) crossref
- De novo peptide sequencing in an ion trap mass spectrometer with 18O labeling (1998) crossref
Cited by (3)
- De novo Peptide Sequencing (2016) crossref
- Bromine isotopic signature facilitates de novo sequencing of peptides in free‐radical‐initiated peptide sequencing (FRIPS) mass spectrometry (2015) crossref
- N-terminal tagging strategy forDe Novosequencing of short peptides by ESI-MS/MS and MALDI-MS/MS (2010) both